Modbus Suite TOP Server + 1 Year Support & Maintenance Agreement
- Details
- Why Choose This Driver?
- Key Features
- Technical Specifications
- Supported Devices
- Industry Applications
- Resources and Documentation
The TOP Server Modbus Suite provides the ultimate in flexibility for connectivity to the widest range of devices supporting the Modbus protocols and integration to other software applications using OPC DA, OPC UA and AVEVA Suitelink. Whether you need Serial, Ethernet or Ethernet/Serial gateway connectivity to Modbus devices, Schneider, Modicon, power distribution, generation & reliability systems or others, this software product gives you a diversity of options, including support for Ethernet/Serial gateways and flexible options to cover the extensive nuances of device implementation of Modbus that challenge other driver solutions.
The TOP Server Modbus Suite is continuously improved based on the change and adaptation of Modbus protocols throughout several market segments. Each driver in the Modbus Suite has configurable options for handling special cases involving the Modbus implementation for a device, making the list of Modbus capable devices that are supported virtually endless.
This item is a Suite of drivers containing:
- Modbus TCP Ethernet Client/Server
- Modbus RTU Serial Client
- Modbus ASCII Serial Client
- Modbus RTU Server Serial
- Modbus Plus
Proven benefits that help you deploy faster and operate more reliably
Maximum Flexibility
Single suite provides connectivity to any Modbus device regardless of protocol variant or network type
Future-Proof Investment
Covers all current and legacy Modbus implementations, protecting your connectivity investment
Vendor Independence
Connect to Modbus devices from any manufacturer without vendor-specific drivers
Cost Effective
Suite pricing provides significant savings versus purchasing individual Modbus drivers separately
Everything you need for reliable industrial connectivity
Advanced Communications Performance
Advanced communications performance handling options with adjustable coil and register blocking for optimal throughput
Flexible Master/Slave Architecture
Flexible architecture supporting both master and slave connections for versatile deployment scenarios
Automatic Tag Generation
Automatic tag generation from Modicon Concept or ProWORX for rapid configuration and deployment
Ethernet Encapsulation
Ethernet encapsulation for Modbus serial protocols via Ethernet-to-serial converters for flexible network topologies
Configurable Addressing
Selectable zero-based vs one-based addressing with byte order swapping support for compatibility
Protocol Variations Support
Support for Modbus language variations used by flow computers (Enron, Omni, Daniel, and others)
Communication
Protocols Supported
Modbus ASCII, Modbus TCP/IP (Ethernet), Modbus Plus, Modbus RTU, Modbus RTU Server, Modbus Unsolicited
Connection Types
Ethernet TCP/IP, Serial RS-232, Serial RS-422, Serial RS-485, Modbus Plus Network
Baud Rates
300 to 115,200 baud (serial variants)
Max Devices per Channel
Unlimited channels and devices per driver
Supported Modbus Device Manufacturers
Modicon
Schneider Electric
Enron
Omni
Daniel
Instromet
Roxar RFM
Mailbox
Elliott
Fluenta FGM
DGH DAQ
Any Modbus-compliant device
Modbus TCP/IP Ethernet Devices
Any device supporting Modbus TCP/IP or Modbus UDP over Ethernet
Modbus RTU Serial Devices
Any device supporting Modbus RTU over serial communications
Modbus ASCII Serial Devices
Modbus RTU Server Serial
Supports Modbus RTU master devices querying TOP Server as a slave
Modbus Plus Devices
Devices on Modbus Plus networks using SA85 or MBPX communication cards
Note: Compatible with thousands of Modbus-enabled devices
Note: Client/Server support for Modbus TCP and UDP
Note: Client support for RS-232 and RS-485
Note: Serial ASCII variant support
Note: TOP Server acts as Modbus RTU slave/server
Note: Modicon Modbus Plus network support
Proven solutions across multiple industries
Multi-Protocol Industrial Environments
Connect to diverse Modbus equipment across manufacturing facilities
Standardize data collection from mixed Modbus networks
Reduce integration complexity with single OPC server
Enable enterprise-wide visibility of Modbus device data
Legacy System Modernization
Bridge legacy Modbus serial devices to modern Ethernet-based systems
Preserve existing serial Modbus investments
Enable cloud connectivity for legacy equipment
Support Industry 4.0 digital transformation initiatives
SCADA and HMI Integration
Provide unified Modbus connectivity for supervisory control systems
Single data source for all Modbus variants
Simplified configuration and maintenance
High-performance real-time data delivery
Everything you need to get started, configure,and troubleshoot your driver
TOP Server Modbus Ethernet Driver Quick Start Video
Video tutorial for Modbus Ethernet driver configuration
TOP Server How-To Videos / Tutorials
Complete library of TOP Server video tutorials