Fisher ROC Suite TOPServer-Unlimited Device License + 1 Year Support & Maintenance Agreement
- Details
- Why Choose This Driver?
- Technical Specifications
- Industry Applications
- Resources and Documentation
- Supported Devices
- Key Features & Benefits
The TOP Server Fisher ROC Suite connects your HMI/SCADA/MES system to your Fisher ROC devices via serial or ethernet encapsulated serial. No tag count limits or limits on # of connected OPC clients. Supports the Remote Operation Controllers (ROC) and ROC Plus Protocols over serial connections or Ethernet connections (including Ethernet encapsulated serial).
This item is a Suite of drivers containing: P/IP connections.
This communications driver is a member of the TOP Server family of products and shares a number of powerful features in common with all of the products in the TOP Server family. The TOP Server family represents the latest in client-server communications technology for connecting HMI, Historian, Database, and other applications to plant floor equipment.
Drivers Included in this Suite:
- →
- →
- →
- →
Proven benefits that help you deploy faster and operate more reliably
Fast Setup & Deployment
Configure in minutes with intuitive setup wizards
Enterprise-Grade Security
Encrypted connections and role-based access control
Real-Time Performance
Sub-second updates with optimized polling algorithms
Unlimited Scalability
Support for hundreds of devices per channel
Communication
Protocols Supported
Remote Operation Controllers (ROC), ROC Plus, TCP/IP, UDP/IP
Connection Types
Ethernet TCP/UDP (including cell modems and radios), Serial RS-232/422/485, Ethernet Encapsulation
Max Devices per Channel
No artificial limits on number of devices or tags
Proven solutions across multiple industries
Upstream Production Monitoring
Monitor wellhead operations including production rates, pressures, temperatures, and tank levels across multiple sites.
✓Real-time production visibility
✓Automated alarm notification
✓Remote configuration management
Pipeline SCADA Integration
Integrate ROC flow computers into pipeline SCADA systems for comprehensive monitoring and control of natural gas transmission.
✓Centralized flow measurement
✓Leak detection support
✓Regulatory compliance reporting
Custody Transfer Metering
Collect accurate flow measurement data for custody transfer applications requiring AGA and API calculations.
✓High-accuracy flow data
✓Audit trail capabilities
✓Historical archive retrieval
Gas Analysis & Quality Monitoring
Monitor gas composition, BTU content, and quality parameters from ROC devices with integrated gas chromatographs.
✓Real-time gas quality data
✓BTU tracking and reporting
✓Contract compliance verification
Everything you need to get started, configure, and troubleshoot your driver
TOP Server Getting Started Video for Fisher ROC
Watch step-by-step video tutorial for Fisher ROC setup
TOP Server How-To Videos / Tutorials
Comprehensive video library for TOP Server configuration
TOP Server How-To Application Notes
Step-by-step guides and application notes
TOP Server Quick Start Guide
Get up and running quickly with this comprehensive guide
TOP Server Troubleshooting Guide
Common issues and solutions for TOP Server
Fisher ROC Ethernet Help File
Complete driver documentation for Fisher ROC Ethernet
Fisher ROC Plus Ethernet Help File
Complete driver documentation for Fisher ROC Plus Ethernet
Fisher ROC Serial Driver Help File
Complete driver documentation for Fisher ROC Serial
Fisher ROC Plus Serial Driver Help File
Complete driver documentation for Fisher ROC Plus Serial
TOP Server Data Sheet
Product overview and technical specifications
Current/Past Release Notes
View the complete TOP Server release history and version information
TOP Server License Agreement
End user license agreement and terms of use
TOP Server Operating System Support Information
Compatible operating systems and requirements
Emerson ROC Protocol Specification
Official ROC protocol documentation from Emerson
Emerson ROC Plus Protocol Specification
Official ROC Plus protocol documentation from Emerson
TOP Server ROC Plus Drivers TLP Addressing Syntax
Technical documentation for TLP addressing
Supported Devices (Don't See Your Device Listed? Contact Us)
- ✓FloBoss 100 Series
- ✓FloBoss 407
- ✓FloBoss 500 Series
- ✓ROC 300 Series - ROCPAC
- ✓ROC 300 Series - FlashPAC
- ✓RegFlo
- ✓ROC809 & ROC809L
- ✓ROC827 & ROC827L
Supported Protocols / Networks
- ✓Remote Operation Controllers (ROC)
- ✓ROC Plus
- ✓tcp/ip
- ✓UDP/IP
- ✓Ethernet (TCP/UDP including Ethernet cell modems and radios)
- ✓Serial RS-232/422/485
- ✓Ethernet Encapsulation
Available Languages
- ✓English
Note: For a complete list of supported models and firmware versions, please contact our technical support team or download the driver documentation.
Real-Time Data Access
Access live process data from your devices with minimal latency and maximum reliability.
Device Configuration
Read and write configuration parameters directly from your SCADA or HMI application.
Automatic Reconnection
Intelligent connection management automatically recovers from network interruptions.
Multi-Protocol Support
Supports multiple communication protocols for flexible deployment options .
High Performance
Optimized algorithms deliver maximum throughput with minimal system overhead.
Diagnostic Logging
Comprehensive logging helps troubleshoot issues and monitor driver performance .